3.
Locate the CMOS clear jumper on the motherboard.
4.
Move the jumper cap from the default pins 1-2 to pins 2-3.
5.
Plug in the power cable and power on the server, and then wait for 10 seconds
for the CMOS to clear.
6.
Power down the server, unplug the power cable, and then wait for 5 seconds
again.
7.
Move the jumper cap back to the default pins 1-2.
8.
Reconnect the power cable and power on the server.

3.5 Layout

Figure 3-7 System Layout
#
Item
1
Front Drive Bays
2
Internal Drive Bays
3
Fan Modules
4
Air Duct
5
Access Panel
6
Rear 2.5-inch Drive Bays
7
Right Riser Card Module
(8-Card Configuration)
8
Middle Riser Card Module
#
Item
13
Plate Capacitor
14
Rear 3.5-inch Drive Bays
15
Processor Heatsink Modules
(PHMs)
16
Rear 2.5-inch Drive Bays
17
Rear M.2 Modules
18
Rear E1.S Modules
19
DIMMs
20
Motherboard
22

Hide quick links: