Operation and Setup, cont'd

I/O presets

Overview

The ISM 824 has a total of sixteen I/O preset memory addresses available. Each
preset can be saved and recalled using the front panel input and output buttons
with presets 1 through 8 assigned to the input buttons, and presets 9 through 16
assigned to the output buttons. Any current tie configuration can be saved to any
one of the preset locations, in any order. Saving the current configuration to an
existing preset overwrites that existing preset in favor of the new configuration.
Likewise, when a preset is recalled, it replaces the current (active) configuration,
which is then lost unless already saved in a previous preset location. The recalled
preset overwrites all of the current configuration ties, in favor of the recalled
configuration. Read all the notes below.
N I/O presets are not the same as memory or user presets, which are used to store
N Presets can not be viewed from the front panel, unless recalled as the current
N Only the audio and video ties are stored and recalled as a preset. Audio gain
N The current configuration and all I/O presets are stored in non-volatile memory.
N When a preset mode is recalled, all the input and output buttons with previously

Saving a preset

To save a preset do the following:
1.
2.
N If no buttons are pressed for 30 seconds after step 2, the Preset mode times out,
Step 1.
Press the Esc button to
clear all selections.
C O N T R O L
ENTER
PRESET
The Esc button flashes
green once.
Step 3.
Figure 3-27 — Steps 1 and 2 for saving a preset
Press and release the desired input or
output button.
3.
1
2
N Input buttons have preset addresses 1 through 8, output buttons have preset
1
2
The Selected button blinks red.
3-20
ISM 824 Integration Scaling Multiswitcher • Operation and Setup
image sizing and centering configurations.
configuration.
settings are not saved, and do not change when a preset is recalled.
When power is removed and restored, the current configuration is active and all
presets are retained.
assigned presets light red.
Press the Esc button to clear all pending changes and reset the LCD.
Press and hold the Preset button until it flashes red. Input and output buttons
light red and the LCD panel shows the preset save mode (see figure 3-27).
and all buttons extinguish.
Step 2.
Press and hold the Preset
button. The button flashes
C O N T R O L
VIEW
ESC
ENTER
PRESET
The input and output buttons light red.
Press and release an input or output button as desired for the address to save
the current configuration. The selected address button, the Preset button, and
INPUTS
the Enter button flash red. The LCD shows the selected preset number (see
3
4
5
6
7
8
figure 3-28).
3
4
5
6
7
8
addresses 9 through 16.
OUTPUTS
P
VIEW
ESC
N The LCD shows the Preset
save mode.
C O N T R O L
ENTER
PRESET
VIEW
The Enter and Preset buttons flash red.
The LCD shows the selected preset
number.
S
ave
P
#11
reset
S
ave
#00
reset
Step 4.
Press and release the
Enter button to save the preset.
ESC
C O N T R O L
ENTER
PRESET
All lights extinguish and the
LCD resets.
VIEW
ESC

Advertisement