Adjusting The Picture Position; Adjusting The Picture Size - Extron electronics ISM 824 User Manual

Extron electronics integration scaling multiswitcher user's manual
Table of Contents

Advertisement

Adjusting the picture position

To adjust the picture position do the following:
1.
2.
N All applicable outputs light or flash green. To change to a different output, press
Step 1.
Step 2.
Press the Esc button to
Press the Position button. The button lights
clear all selections.
green.
C O N T R O L
ENTER
PRESET
VIEW
ESC
The Esc button flashes
Out #5
green once.
N The LCD shows the current position setting.
Figure 3-36 — Steps 1 and 2 for adjusting picture position
3.
N The horizontal adjustments values are:
N The vertical adjustments values are:
4.

Adjusting the picture size

To adjust the picture size do the following:
1.
2.
N All applicable outputs light or flash green. To change to a different output, press
ISM 824 Integration Scaling Multiswitcher • Operation and Setup
Press the Esc button to clear all pending changes and reset the LCD.
Press and release the Position adjustment button. The output buttons for
scaler /scan converter cards (outputs 3 through 8) and any associated (tied)
input buttons light solid green. Untied outputs flash green. The LCD panel
shows the current position setting (see figure 3-36) for that lit output.
the desired output button. The selected button will light green.
BRIGHT/
COLOR/
DETAIL
POSITION
SIZE
CONT
TINT
PICTURE ADJUSTMENTS
p
i
i
os
t
on
H=+0000
V=+0000
Use the left front panel encoder (
for the Universal Scaler card (-2047 to +2047, default is +0000)
for the Video Scaler card (-127 to +127, default is +0000)
A setting increment moves the whole picture to the right, and a setting
decrement moves the whole picture to the left. The vertical alignment does not
change.
Use the right front panel encoder (
for the Universal Scaler card (-2047 to +2047, default is +0000)
for the Video Scaler card (-127 to +127, default is +0000)
A setting increment moves the whole picture down, and a setting decrement
moves the whole picture up. The horizontal alignment does not change.
Press the Esc button to clear all button and reset the LCD.
Press the Esc button to clear all pending changes and reset the LCD.
Press and release the Size adjustment button. The output buttons for scaler
/scan converter cards (outputs 3 through 8) and any associated (tied) input
buttons light solid green. Untied outputs flash green. The LCD panel shows
the current size setting (see figure 3-37) for that output.
the desired output button. The selected button will light green.
2
3
1
ZOOM
1
2
3
The last selected scaler output card button (#5) and associated
input (#2) light green. Applicable available outputs flash green.
[
to adjust the horizontal position.
)
{
to adjust the vertical position.
)
INPUTS
6
4
7
5
8
4
5
6
7
8
OUTPUTS
3-25

Advertisement