Picture adjustments

The ISM 824 has six buttons for picture
adjustment modes (color/tint, brightness/
contrast, detail, position, size, and zoom).
COLOR/
BRIGHT/
DETAIL
POSITION
TINT
CONT
PICTURE ADJUSTMENTS
To make picture adjustments do the following:
1.
Press the Esc button.
2.
Press the applicable picture adjustment
button (lights amber). Associated output
buttons for cards that allow adjustments
light steady or flash green. If flashing, press
the button to select (lights green).
Steady lit buttons indicate currently
N
selected outputs, and flashing buttons
indicate outputs available for selection.
Step 2.
Press the Color/Tint button.
The button lights amber.
COLOR/
BRIGHT/
DETAIL
POSITION
TINT
CONT
PICTURE ADJUSTMENTS
Col Out #5 Tint
128
N The LCD shows the current Color/Tint setting.
INPUTS
1
2
3
4
1
2
3
4
OUTPUTS
The applicable output card button (#5) and associated
input (#2) light green. Applicable available outputs flash
green.
Step 3.
Use the encoders to make
the adjustment.
3.
Use the appropriate encoder to make the
desired adjustments.
4.
Press the Esc button to exit. The buttons
extinguish.
See
chapter 3, "Operation and Setup", "Picture
adjustments"
section, for information about all
picture adjustment settings.
SIZE
ZOOM
SIZE
ZOOM
128
5
6
7
8
5
6
7
8
ADJUST
ISM 824 Integration Scaling Multiswitcher • Quick Start
Presets
The ISM 824 has a total of sixteen I/O preset
memory addresses available that are assigned
to the input and output buttons. They can be
saved and recalled using the front panel and any
current tie configuration can be saved to any one
of the preset locations, in any order.
N
Saving the current configuration to an
existing preset overwrites that existing
preset in favor of the new configuration.
To save or recall a preset, do the following:
1.
Press the Esc button.
2.
Press and hold (2 seconds for save) or press
and release the Preset button (to recall). The
Preset button either flashes red (save) or
lights red (recall).
3.
Select the desired input or output button for
the appropriate preset number (1-16) to save
to or recall from. That button and the Enter
button flash red.
Step 2. Press the Preset button
To save a preset
2 seconds
OR
PRESET
PRESET
Press and
Preset button
hold
flashes red.
Step 3. Select desired preset #
Preset numbers (1-16)
1
2
3
4
5
INPUTS
1 2 3 4 5 6 7 8
1 2 3 4 5 6
OUTPUTS
10
9
11
12
13
Whenever the preset button is pressed, currently saved
preset buttons light red (e.g. presets #'s 3, 5,and 15).
Select a new
preset # to save to.
6
OR
Step 4. Press the flashing Enter button to excute.
ENTER
4.
Press Enter. All preset buttons and the
Enter buttons extinguish. The current
configuration is saved to or retrieved from
the selected preset location.
See
chapter 3, "Operation and Setup", "I/O
presets"
section, for further information.
To recall a preset
PRESET
PRESET
Press and
Preset button
release
lights red.
6
7
8
7 8
14
15
16
Select an existing
preset to recall.
3
QS-3

Advertisement

Table of Contents
loading

Table of Contents