Operation and Setup, cont'd
Editing the communication settings
To edit the communication settings, do the following:
N The hardware address (the MAC address) is hard coded and cannot be changed.
1.
2.
3.
4.
5.
N The hardware address (the MAC address) is hard coded and cannot be changed.
6.
7.
8.
9.
10.
11.
12.
13.
14.
N Press the Menu button to go directly to the next top level (System Reset) menu.
3-42
ISM 824 Integration Scaling Multiswitcher • Operation and Setup
In edit mode the MAC addresss menu is not displayed.
Press the Enter, Preset, View, and Esc buttons at the same time, and hold
down for 2 seconds. The LCD displays the Edit Comm Settings menu.
Press the Next button to enter the first sub level, Remote Port.
Rotate the left front panel encoder (
38400, or 115200), and rotate the right encoder (
type (RS-232/RS-422).
Press Next to go to the front panel's Config Port menu.
Rotate the left front panel encoder (
38400, or 115200), and rotate the right encoder (
type (RS-232).
In edit mode the MAC addresss menu is not displayed.
Press Next to go to the DHCP Mode menu. From this menu, DHCP (Dynamic
Host Configuration Protocol) can be turned on or off. Default setting is off.
Rotate either front panel encoder to turn the DHCP mode on or off.
Press Next to go to the IP Address menu. In this menu the IP address of the
ISM 824 multiswitcher can be changed as desired. Valid IP addresses consist
of four 1-, 2-, or 3-digit numeric subfields separated by dots (periods). Each
field can be numbered from 000 through 255. Leading zeroes, up to 3 digits
total per field, are optional. Values of 256 and above are invalid. The default
IP address is 198.162.254.254.
Rotate the left front panel encoder (
field value flashes when selected), then rotate the right encoder (
the field values.
Press Next to go to the Subnet Mask menu. In this menu the Subnet mask
of the ISM 824 multiswitcher can be changed as desired. The default is
255.255.000.000
Rotate the left front panel encoder (
{
rotate the right encoder (
Press Next to go to the Gateway Address menu. In this menu the Gateway
address of the ISM 824 multiswitcher can be changed as desired. The default
is 000.000.000.000
Rotate the left front panel encoder (
{
rotate the right encoder (
Press Next to return to the upper level Edit Comm Settings menu.
[
) to adjust the baud rate (9600, 19200,
{
) to select the connection
[
) to adjust the baud rate (9600, 19200,
{
) to select the connection
[
) to select the field to be changed (the
[
) to select the field to be changed, then
) to change the field values.
[
) to select the field to be changed, then
) to change the field values.
{
) to change