YASKAWA LonWorks SI-W3 Installation Manual page 43

Hide thumbs Also See for LonWorks SI-W3:
Table of Contents

Advertisement

1.
Prepare the communication cables as shown in
A - Sheath
B - Shield
2.
Connect the communication cables to the terminal block as shown in
Make sure that the terminal block CN1 is firmly fixed when you connect the
terminal block CN1 to the circuit board.
Tighten the screws to a correct tightening torque:
• 0.22 to 0.25 N•m (0.0 to 0.0 in•lb)
3.
Make sure that you correctly connect the wires and that you did not accidentally
pinch wire insulation in the terminals.
Trim any frayed wires.
WARNING
torque. Connections that are too loose or too tight can cause incorrect operation and damage
to the drive. Incorrect connections can also cause death or serious injury from fire.
NOTICE
the wire shields with electrical tape or shrink tubing. If you do not insulate the wire shields, it
can cause a short circuit and damage the drive.
Figure 5.30 Prepare and Connect Communication Cable Wiring
YASKAWA TOEP C730600 93B LonWorks Installation Manual
Figure 5.29 Prepare Ends of Shielded Cable
Fire Hazard. Tighten all terminal screws to the correct tightening
Do not let wire shields touch other signal lines or equipment. Insulate
Figure
5.29.
C - Use electrical tape or shrink
tubing to insulate the cable.
5 Installation Procedure
Figure
5.30.
43

Advertisement

Table of Contents
loading

Table of Contents