MAINTENANCE
2.
Hold outer element (5), rock it lightly up and down and to the right and left, and twist it clockwise and coun-
terclockwise, and pull it out.
Do not remove inner element (6) at this time.
3.
When outer element (5) is removed, check that the inner
element does not come out of position and is not at an an-
gle.
If the inner element is inclined, push it in straight by hand
to the end.
4.
Clean dusts in inside and on cover (3) of air cleaner body
(7) by using a clean cloth or brush.
5.
If any dust is attached to vacuator valve (4) installed to
cover (3), remove it.
6.
Remove inner element (6), then quickly install the new in-
ner element.
Install the inner element securely so that it does not move.
7.
Push new outer element (5) in straight with your hand into
the air cleaner body.
Hold the element, and rock it lightly up and down and to
the right and left while pushing it in, the element can be inserted easily.
8.
Install cover (3) according to the following procedure.
1)
Check that O-ring (8) is fitted to cover (3).
2)
Align cover (3) with the element.
3)
Lock the tip of hook (2) on the protrusion of the air
cleaner body.
4)
Lock hooks (2) diagonally, (top and bottom, right and
left) in the same way as when tightening the bolts.
MAINTENANCE PROCEDURE