Komatsu PC210LC-11 Operation & Maintenance Manual page 165

With continuous camera view
Hide thumbs Also See for PC210LC-11:
Table of Contents

Advertisement

OPERATION
Use room lamp switch to light up the room lamp.
(a) ON position
Lights up
(b) OFF position
OFF
The room lamp lights up even when the starting switch is at
OFF position.
PUMP SECONDARY DRIVE SWITCH
k
k
When pump secondary drive switch (1) is being used or
immediately after it is used, the temperature of resistor (2)
under the fuse may become high.
When operating the switch or replacing the fuse, take care
not to touch resistor (2).
NOTICE
The pump secondary drive switch enables you to per-
form operation temporarily when any problem occurs
on the pump control system. Do not use it except for
emergency. Repair the problem as soon as possible.
If this switch is moved to "Emergency" position by
mistake while the machine is operating normally,
"L03" appears in the display.
If "L03" is displayed during operation, press the moni-
tor function switch F5 to check whether the current
failure code includes any of the hydraulic system er-
rors "DXA9KB", "DXA8KB", "DXA9KA" or "DXA8KA".
Then make sure this switch is set to "Normal" posi-
tion.
The pump secondary drive switch enables you to perform oper-
ation temporarily when any problem occurs on the pump con-
trol system.
(a) Emergency
When abnormal (switch is set to upper position)
(b) Normal
When normal (switch is set to lower position)
CAUTION
EXPLANATION OF COMPONENTS
KS000911
3-91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc210-11Pc210nlc-11Pc230nhd-11

Table of Contents