EXPLANATION OF COMPONENTS
2.
The "Breaker Oil Flow Rate Setting" screen is displayed.
On the "Breaker Oil Flow Rate Setting" screen, you can
perform the following operations with switches F3 to F6.
F3: Decreases the flow by 1 level.
F4: Increases the flow by 1 level.
F5: Returns the screen to the "Breaker Setting" screen
without changing the oil flow.
F6: Enters the oil flow rate setting and returns the screen
to the "Breaker Setting screen".
(X): Present oil flow setting
(Y): Min. oil flow for adjustment
(Z): Max. oil flow for adjustment
ATTACHMENT SETTING
On machines ready for installation of attachment, you can adjust the oil flow rate in ATT/P mode and ATT/E
mode to match the attachment on the "Attachment Setting" menu.
For machines that have no attachment, the "Attachment Setting" menu is not displayed.
1.
Select "Attachment Setting" (3) on the "Machine Setting"
menu (b) screen, then press switch F6.
2.
On the "Attachment Setting" screen shown in the figure,
select an attachment to adjust and press switch F6.
On the "Attachment Setting" screen shown in the figure,
you can perform the following operations with switches F1
to F6.
F1: Changes the name of the selected attachment setting.
F2: Changes the oil flow rate of the selected attachment
setting.
F3: Moves to the next item (1 line below). When on the last
line, it moves to the first line.
F4: Moves to the previous item (1 line above). When on the first line, it moves to the last line.
F5: Cancels the selection and returns the screen to the "Machine Setting" menu screen.
F6: Allocates the selected setting to that of ATT/P or ATT/E mode.
Changing "Attachment Setting" name
It is possible to change the attachment setting name as you like.
You can use alphabet letters A to Z, Arabic numerals 0 to 9, symbols #, *, +, -, and /, and the space.