Komatsu PC210LC-11 Operation & Maintenance Manual page 139

With continuous camera view
Hide thumbs Also See for PC210LC-11:
Table of Contents

Advertisement

OPERATION
On the Configurations screen, it is possible to perform the fol-
lowing operations with switches F3 to F6.
F3: Moves to the next item (1 line below). When on the last
line, it moves to the first line on the next page.
F4: Moves to the previous item (1 line above). When on the
first line, it moves to the last line on the previous page.
F5: Cancels the setting change and returns to Configurations
screen.
F6: Changes the setting and returns to Configurations screen.
SET TARGET FUEL CONSUMPTION VALUE DISPLAYED IN ECO GAUGE
It is possible to change the target fuel consumption value (the upper limit value of the green range) of the ECO
gauge .
1.
Select the ECO Gauge Target Value (9) from the Configu-
rations screen, then press switch F6.
2.
ECO Gauge Display Fuel Target Value appears.
On this screen, it is possible to perform the following oper-
ations with switches F3 to F6.
F3: Decreases the target fuel consumption value by 1 ℓ/h.
F4: Increases the target fuel consumption value by 1 ℓ/h.
F5: Cancels the setting and returns to Configurations
screen.
F6: Changes the setting and returns to Configurations
screen.
SWITCH DISPLAY/NON-DISPLAY OF ECO GUIDANCE
It is possible to change the setting of Display/Non-display of
ECO guidance (10).
EXPLANATION OF COMPONENTS
3-65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc210-11Pc210nlc-11Pc230nhd-11

Table of Contents