MAINTENANCE PROCEDURE
1)
Check that O-ring (8) is fitted to cover (3).
2)
Align cover (3) with the element.
3)
Lock the tip of hook (2) on the protrusion of the air
cleaner body.
4)
Lock hooks (2) diagonally, (top and bottom, right and
left) in the same way as when tightening the bolts.
5)
Always install cover (3) so that vacuator (4) faces the
ground (A).
6)
When cover (3) is installed, check that the clearance
between the air cleaner body and cover (3) is not too
large.
If the clearance is too large, remove cover (3), and
then install it again.
16. Check that air cleaner clogging caution lamp (1) on the
monitor panel.
If it light up just after cleaning of the elements has been
finished, replace the inner and outer elements.
METHOD FOR CHANGING AIR CLEANER ELEMENT
NOTICE
Do not clean and reuse the inner element. When replacing the outer element, replace the inner ele-
ment with a new one at the same time.
If the outer element and cover are installed while the inner element is not installed properly, the out-
er element may be damaged.
The sealing portion of the improper part lacks precision, and allows the entry of dust, which leads
to damage of the engine. Do not use such improper part.
Replace the outer element in the following procedure.
1.
Open the door at the rear left side of the machine and re-
move hooks (2) (4 places) to remove cover (3).