Setting Command

5-6-7 Communications Port Setting Command (CP)

This command sets the baud rate for the communications port (COM Port), data length, parity bit,
and stop bit for use in communications with the host.
<Command Format>
STX
Node No.
1
2
Port No.
Baud rate
Data length
Parity bit
Stop bit
BCC En-
abled/Disabled
ACK/NACK
Timeout
ACK/NACK timeout
period setting
5-42
Command
Port
Baud
Data
code
No.
rate
length
"CP"
2
1
1
Specify the port number that you want to change in decimal.
Specification range: 1 or 2
Specification number
Port
COM1
Specify the number corresponding to the baud rate that you want to change.
Specification range: 0 to 3, *
When * is specified, the Reader/Writer reads the current setting.
Specified
number
0
Baud rate
9600 bps
Specify the number corresponding to the data length that you want to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
Data length
Specify the number corresponding to the parity bit that you want to change.
Specification range: 0, 1, 2, *
When * is specified, the Reader/Writer reads the current setting.
Specification
number
0
Parity
No
Specify the number corresponding to the stop bit that you want to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
0
Stop bit
1 bit
Specify the number corresponding to the BCC setting that you want to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
BCC
Enabled
Specify the number corresponding to the communications mode that you want
to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
ACK/NACK Control
Disabled
Specify the number corresponding to the timeout period that you want to
change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
Timeout period
Parity
Stop
BCC
bit
bit
Enabled
/Disabled
1
1
1
1
1
2
COM2
1
2
19200 bps
38400 bps
0
1
*
7Bit
8Bit
-
1
2
Odd
Even
1
*
2 bits
-
0
1
*
Disabled
-
0
1
*
Enabled
-
0
1
*
5 sec
0.5 sec
-
Section 5-6
ACK
time-
ETX BCC
NACK
out
1
1
1
1
3
*
115200 bps
-
*
-