System Lock (Sl): Iso Mode Only - Omron V720S Series Operation Manual

Electromagnetic inductive rfid system reader/writer
Table of Contents

Advertisement

System Command

5-4-3 System Lock (SL): ISO Mode Only

This command locks (write-inhibit) to write to system area information of a Tag.
<Command Format>
(1) Normal lock
STX
Node No.. Command code
1
2
(2) In a case where UID of a Tag is specified
STX
Node No.. Command code
1
2
Tag type
System method
UID
Response Format>
STX
Node No..
1
2
Response code
!
Caution
Tag
System
"SL"
type
method
2
1
2
Tag
System
"SL"
type
method
2
1
2
Specifies the Tag type.
A: I.CODE2 chip
Specifies the system information to lock.
01:AFI
02: DSFID
03: EAS (normal lock)
83: Select EAS (In a case where UID of a Tag is specified and locked)
Specifies the UID of a Tag to lock in hexadecimal.
Retry
Response code
Command code
"00"
flag
"SL"
1
2
2
00:normal completion
For other response codes, refer to 5-2-4 Response code List.
Note This command is in ISO Mode Only. The command is not available for
I.CODE1 mode.
Be careful that once system information has been locked, the lock cannot
be cleared.
Note This command is in ISO mode Only. The command is not available for
I.CODE1 mode.
ETX BCC
1
1
ETX BCC
UID
16
1
1
ETX BCC
1
1
Section 5-4
5-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

V720s-bc5d4