Snr Addition Setting (Sn) - Omron V720S Series Operation Manual

Electromagnetic inductive rfid system reader/writer
Table of Contents

Advertisement

Setting Command

5-6-5 SNR Addition Setting (SN)

This command selects whether SNR will be added to a response to a Read Command (excluding
Special Read).
<Command Format>
STX
Node No.
1
2
Addition mode
<Response Format>
STX
Node No.
1
2
Response code:
addition mode
<Response when setting is invalid>
STX
Node No.
1
2
<Response when setting is valid>
STX
Node No.
1
2
Response code:
SNR
Read data
!
Caution
5-40
Command
Addi-
ETX BCC
code
tion
"SN"
mode
2
1
1
Specify whether SNR will be added to a response.
Setting range: 0 to 1, or *
When * is specified, the Reader/Writer reads the number that is
currently set.
Specification
0
number
SNR addition
Disabled
mode
Retry
Command
Response
flag
code
code:
"SN"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Indicates the number corresponding to the specified addition mode.
Retry
Command
Response
flag
code
code:
"RD"
"00"
1
2
2
Retry
Command
Response
flag
code
code:
"RD"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Indicates the SNR read from the Tag.
Indicates the data read from the Tag.
SNR cannot be added to a response to the Special Read Command (refer
to 5-3-8 Special Read).
Note • The setting becomes effective after resetting using the Reset Command.
• In order to make your setting survive system shutdown, you need to save
the Setting Write Command (refer to EW Command in 10, 5-2-4) in the
EEPROM.
1
1
Enabled
ETX BCC
1
1
Read data
As specified
SNR
8
Section 5-6
*
-
ETX BCC
1
1
Read data
ETX BCC
As specified
1
1