Assembly Of Connector; Assembly Of Host Communications Connector And I/O Connector - Omron V720S Series Operation Manual

Electromagnetic inductive rfid system reader/writer
Table of Contents

Advertisement

Wiring Method

4-4-3 Assembly of Connector

4-4-3-1 Assembly of Host Communications Connector and I/O Connector

Clamp nut
Set screw B
• Cable terminal treatment measurement table
Usage
Host communica-
tions/IO
Power supply
4-14
1) Disassemble the connector as follows:
a) Loosen the set screws and remove the barrel from the end bell (by
turning it counterclockwise).
b) Loosen Set Screw B, remove the clamp nut from the end bell, and pull
out the washer and the cable packing.
Cable packing
Washer
2) Draw the cable through the disassembled parts in the order shown below.
・ Make sure that the parts are in the correct order and orientation.
Clamp nut
Set screw B
3) Strip a part of the sheath and insulator of each cable to be used according
to the measurements specified in the table below.
Envelope
Connector name
NJW-165 + PF, PM, AdF
NJW-2010 + PF, PM, AdF
4) Pre-solder the conductors complete with terminal treatment.
Note • Be careful not to pre-solder the cable cladding.
• When finished, the pre-soldered part should be smaller in diameter than the
contact hole and have no uneven portion on the entire surface.
Coupling nut
End bell
Set screw A
End bell
Cable packing
Washer
Set screw A
Conductor envelope
Mesure-
ment A
(mm)
16
18
Coupling nut
Mesure-
Conductor
ment B
cross-sec-
(mm)
tional area
2
(mm
)
3.2
0.5
Section 4-4
Barrel
Cable
Iron tip
tempera-
ture(%)
280
350