Terminal Resistance Setting Command (Tm) - Omron V720S Series Operation Manual

Electromagnetic inductive rfid system reader/writer
Table of Contents

Advertisement

Setting Command

5-6-11 Terminal Resistance Setting Command (TM)

This command sets and reads the terminal resistance (for RS-485).
<Command Format>
STX
Node No.
1
2
Terminal
specification
<Response Format>
STX
Node No.
1
2
Response code
Terminal setting
5-46
Command
Terminal
ETX BCC
code
specifi-
"TM"
cation
2
1
1
Specify the value, 0 or 1, that corresponds to the terminal resistance that
you want to change.
Specification range: 0, 1, or *
When * is specified, the Reader/Writer reads the current setting.
Specification number
Retry
Command
Response
flag
code
code
"TM"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Indicates the setting corresponding to the specified terminal resistance in
decimal.
Note • The setting becomes effective after resetting using the Reset Command.
• In order to make your setting survive system shutdown, you need to save
the Setting Write Command (refer to EW Command in 10, 5-2-4) in the
EEPROM.
1
0
1
*
OFF
ON
-
Terminal
E
BCC
setting
T
X
1
1
1
Section 5-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

V720s-bc5d4