Reader/Writer Control Command

5-5-6 Test (TS)

This command returns test messages sent from the host with no change made. The test command
is used for testing communications between the host and the Reader/Writer and other purposes.
<Command Format>
STX
Node No.
1
2
Test message
<Response Format>
STX
Node No.
1
2
Response code
Test message
5-34
Command
Test message
code
"TS"
2
The number of characters from 0 up to 64 max is available.
Retry
Command
Response
flag
code
code
"TS"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Returns the test message received using commands.
ETX BCC
1
1
Test message