Setting Command

5-6-4 Read and Write of Application (AI): I.CODE1 Mode Only

This Command is used to set or read and read the application ID in the Reader/Writer in 1.CODE1
Mode Only Tags that have the same application ID as the one set by this command can perform
communications. If the application ID in the Reader/Writer is set to 00, communications will be pos-
sible with all Tags.
<Command Format>
Node No.. Command code
STX
1
2
Application ID
<Response Format>
STX
Node No..
1
2
Response code
Application ID
Application ID ETX BCC
"AI"
2
2
The application ID is designated in hexadecimal.
Specification range: 00h to FFh
When the application ID is set to "**," the application ID currently set in the
Reader/Writer will be read.
Retry
Command code
Response
flag
"AI"
code
"00"
1
2
2
00:normal completion
For other response codes, refer to 5-2-4 Response code List.
Indicates current Application I in hexadecimal.
Note • A setting becomes valid after executing Reset Command. To keep the
setting valid next startup, you need to save with Setting Write Command
(refer to 5-6-14 EW Command).
• This command is for I.CODE1 Mode Only. The command is not available
in ISO mode.
1
1
Application ID ETX BCC
2
1
1