5-6-12 Offline Mode Setting (FL)

This command selects whether the Reader/Writer will start in offline mode or offline mode.
When offline mode is selected, the Reader/Writer will perform EAS check independent of the host,
and output a signal from the output port (OUT1) if the result exceeds the specified criterion.
<Command Format>
STX
Node No.
1
2
On/OFF mode
Time (*100ms)
Threshold (%)
<Response Format>
STX
Node No.
1
2
Response code:
On/OFF mode
Time
Threshold
Command
On/OFF
Time
code
mode
"FL"
2
1
Specify the number corresponding to the mode in which the Reader/Writer
will start.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification
0
number
On/OFF mode
Online mode
Specify the length of time in HEX for which the signal will be output to
OUT1 in offline mode.
Specification range: 01 to FFh (100ms to 22.5s)
When * is specified, the Reader/Writer reads the current setting.
Specify the threshold in HEX to be output to OUT1 in offline mode.
Specification range: 00h to 64h (%)
(Refer to EAS Check Command.)
When * is specified, the Reader/Writer reads the current setting.
Retry
Command
Response
flag
code
code:
"FL"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Indicates the number corresponding to the specified On/Off mode.
Indicates the time corresponding to the specified On/Off mode.
Indicates the criterion corresponding to the specified On/Off mode.
Note • The default value for the threshold is 19 h (25%) and that for the output
time is 500 ms.
• The setting becomes effective after resetting using the Reset Command.
• In order to make your setting survive system shutdown, you need to save
the Setting Write Command (refer to EW Command in 10, 5-2-4) in the
EEPROM.
• The command related to this is the EAS Setting (refer to EA Command in
6, 5-2-2) and EAS Check (refer to EA Command in 7, 5-2-2).
Threshold
ETX BCC
1
2
2
1
Offline mode
On/OFF
Time
mode
2
1
1
*
-
Threshold ETX BCC
2
1
1
Section 5-6
5-47