Setting Command

5-6-9 Tag Communications Mode (CM)

This command sets and reads the communications mode for use in communications with Tags.
<Command Format>
STX
Node No.
1
2
Communica-
tions mode
<Response Format>
STX
Node No.
1
2
Response code
Communications
mode
5-44
Command
Commni-
ETX BCC
code
cations
"CM"
mode
2
1
1
Specify the number corresponding to the communications mode
that you want to select for communications with Tags.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification
0
number
Tag communi-
Standard
cations mode
Mode
Retry
Command
Response
flag
code
code:
"CM"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Indicates the number corresponding to the specified terminal resistance.
Note • The setting becomes effective after resetting using the Reset Command.
• In order to make your setting survive system shutdown, you need to save
the Setting Write Command (refer to EW Command in 10, 5-2-4) in the
EEPROM..
1
1
Fast Mode
Com-
ETX BCC
muni-
cations
mode
1
1
1
Section 5-6
-