Initialization Of Settings Command (Is); Setting Write Command (Ew) - Omron V720S Series Operation Manual

Electromagnetic inductive rfid system reader/writer
Table of Contents

Advertisement

Setting Command

5-6-13 Initialization of Settings Command (IS)

If necessary, you can return all the settings to their factory settings.
<Command Format>
STX
Node No.
1
2
<Response Format>
STX
Node No.
1
2
Response code:

5-6-14 Setting Write Command (EW)

This command is executed to make the settings made using the commands from 1} to 9} survive
shutdown of the Reader/Writer.
<Command Format>
STX
Node No.
1
2
<Response Format>
STX
Node No.
1
2
Response code:
5-48
Command
ETX BCC
code
"IS"
2
1
1
Retry
Command
Response
flag
code
code:
"IS"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Note • The setting becomes effective after resetting using the Reset Command.
• In order to make your setting survive system shutdown, you need to save
the Setting Write Command (refer to EW Command in 10, 5-2-4) in the
EEPROM..
Command
ETX BCC
code
"EW"
2
1
1
Retry
Command
Response
flag
code
code:
"EW"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Note • On successful completion of this command, the settings are written to the
nonvolatile memory (EEPROM) of the Reader/Writer. Once the EW com-
mand has been executed, all the settings made up to this point in time are
written to the nonvolatile memory, thereby eliminating the need to execute
this command every time you make a setting.
• Unless you execute the EW command, the settings you have specified will
return to the previous values next time you start the Reader/Writer.
ETX BCC
1
1
ETX BCC
1
1
Section 5-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

V720s-bc5d4

Table of Contents