Timeslot Setting - Omron V720S Series Operation Manual

Electromagnetic inductive rfid system reader/writer
Table of Contents

Advertisement

Timeslot Setting

5-10 Timeslot Setting

The timeslot setting is the setting in the command frame when communicating with multiple Tags
simultaneously using Multi-system commands. This setting must be set according to the number of
Tags with which to communicate simultaneously. Refer to the table below for the relationship be-
tween the number of Tags and this setting.
Example: If the number of Tags is seven, select Tag Number setting 3.
Max. No. of Tags with which simultaneous communi-
Timeslot setting
0
1
2
3
4
5
6
7
Note • If more Tags than have been set using the timeslot setting enter the
communications range, a "70" error (warning) may occur. (e.g., When
the timeslot setting is "2" and there are five Tags in the communications
area.)
Select a suitable setting by referring to the above table.
• For the Special Read (refer to 5-2-1-6) command, the anti-collision proc-
ess is not performed. Therefore, read data will be returned even If there
are more Tags than the timeslot setting in the communications area.If a
collision occurs, such data will not be returned.
• The higher the timeslot setting is, the longer the communications time is
required. Consequently, setting a higher timeslot setting than required for
the number of Tags in use unnecessarily lengthens communications time,
so select a suitable setting.
cation is possible
1
~2
~4
~8
~16
~32
~64
~128
Section 5-10
5-63