Setting Command

5-6

Setting Command

5-6-1 Reader/Writer AFI Enable/Disable Changeover (AE): ISO Mode
Only
In ISO mode, you must set AFI of the Reader/Writer either enable or disable when communicating
with a Tag. If you set AFI enable, only Tags, which has the same AFI, can be communicated. When
you set AFI disable, the communications are enabled no matter AFI in Reader/Writer is set or not.
<Command Format>
Node No.. Command code
STX
1
2
AFI enable/disable
<Response Format>
STX
Node No..
1
2
Response code
AFI valid/invalid
5-36
AFI
ETX BCC
Set-
"AE"
ting
2
1
1
Specifies either valid or invalid of AFI setting in Reader/Writer.
0: invalid (factory setting)
1: valid
For "*", the Reader/Writer reads and writes current settings.
Retry
Command code
Response
flag
"AE"
code
"00"
1
2
2
00:normal completion
For other response codes, refer to 5-2-4 Response code List.
Indicates valid/invalid of AFI in hexadecimal.
Note • A setting becomes valid after executing Reset Command. To keep the
setting valid next startup, you need to save with Setting Write Command
(refer to 5-6-14 EW Command).
• This command is for ISO Mode Only. The command is not available in
I.CODE1 mode.