6.6
Replacing the intake filter
(test oil filter and fine filter)
and the test oil filter (cooling)
The instructions below describe the replacement of
the fine filter and calibrating oil filters. On the intake
filter, the test oil filter and the fine filter must always be
replaced together.
i
For disposal of calibrating oil and filters, see sec. 7
"Shutdown".
Fig. 14:
Fine filter, calibrating oil filters
1 Drain hose for calibrating oil
2 Test oil filter (cooling)
3 Intake filter (fine filter)
4 Intake filter (test oil filter)
6.6.1
Replacing the test oil filter (cooling)
i
The intake filter (test oil filter) is replaced in the
same way as the test oil filter (cooling). The filter
element's seal provided is to be mounted in the filter
cover. The seal must always be replaced together
with the filter.
1. Exit all open applications.
2. Shut down the PC via the Windows operating
system.
3. Switch off the EPS 708 via the master switch.
Robert Bosch GmbH
4. Take off the front right cover (fig. 1, pos. 2).
5. Remove the Allen screw (fig. 15, pos. 1).
1
Fig. 15:
1 Allen screw
2
2 Mounting bracket
6. Assemble the mounting bracket (with the filters).
3
4
Fig. 16:
7. Fit the mounting bracket (with the filters) in the
front recesses (see fig. 16).
Maintenance | EPS 708 | 55
1
2
Detaching the mounting bracket
Fitting the mounting bracket
1 689 989 067