Information; Log File - Pilz PSEN sc M 3.0 08-12 Operating Manual

Hide thumbs Also See for PSEN sc M 3.0 08-12:
Table of Contents

Advertisement

Operation
10.3.3

Information

Message in the display
Icon
Text
CLEANW2
DLDNC
DLDNF
ITLOCK1
WAITING
CONF
10.3.4

Log file

A series of events is stored in a log file.
The file is saved in the memory module and synchronously also in the safety laser scanner.
}
Events at the safety outputs (violations of the safety zone)
}
Events at the inputs for muting and override
}
Error
}
Updates (firmware, configurations etc.)
}
Restoring of configurations
}
Current configuration of zone sets
}
Exchange of PSEN sc head
The log file is saved in csv format.
The file is saved in the memory module and synchronously also in the safety laser scanner.
An entry is created in the log file for each logged event.
Format of the entries:
<Date> <Time> <Event type <Details on the event>
Example of a mistake:
10-Sep-20 5:24:30 PM;FAULT;FAULT INPUTCF2
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
Error/cause
The font panel of the safety laser
scanner is contaminated and it must
be cleaned to ensure normal opera-
tion.
A new configuration is downloaded.
A new firmware version is down-
loaded.
OSSD must be restarted
The safety laser scanner waits for a
configuration (e.g. after restoring a
configuration).
Description/measure
Clean front panel
Perform a
reset of the safety laser
scanner [
95].
Configure the safety laser scanner
(see
Configuration of
zones [
78]).