Project configuration
5.7
Ambient conditions
}
Information given in the
}
If there is a highly reflective background within a distance of 2.5 m from the safety zone
perimeter (e.g. a shiny metallic surface), errors in the calculation of the exact distance to
the detected object may occur.
– Reduce the reflection of the background or remove the background or
– add the allowance Z
}
Avoid strong electromagnetic interference when operating the safety laser scanner.
}
When operating the safety laser scanner, avoid strong smoke, mist, and dust formation
that would reduce the safety laser scanner's operating range or lead to switching to the
OFF state.
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
Technical details [
to the minimum safety distance (see
R
sources and to reflective surfaces [
106]
must be followed.
Distance to intense light
40]).
| 39