Project configuration
5.1.4

Vertical application

A vertical application is given when the safety laser scanner is aligned at an angle of over
± 30° with the floor level.
Fig.: Schematic representation of a vertical application on a passage
Legend
[1] Danger zone
[2] Area covered by the laser beam
[3] Safety laser scanner
The following applies for these applications:
S = K * (t
S
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
CAUTION!
Risk of injury due to insufficient safeguard
Reaching into the opening between safety laser scanner and mounting area
can lead to injuries.
– Prevent reaching into the opening by using a suitable safeguard.
+ t
) + Z
+ Z
+ C
1
2
T
R
Minimum distance in mm, measured from the start of the protective zone to the
danger source
[1]
[3]
[2]