PSENscan Configurator
8.2.3
Ethernet Connections
8.2.3.1
Factory default settings for the IP addresses
The factory-set default of the IP address of the safety laser scanner: 192.168.0.10.
8.2.3.2
Create firewall rule
A firewall or any other security mechanisms on the PC and network may prevent the
PSENscan Configurator from communicating correctly with the connected devices. In this
case, it will be necessary to adjust the security settings and firewall settings.
Firewalls allow access to explicitly registered programs. The following program must have
access to the profile Private:
}
PSENscan Configurator
8.2.3.3
Connect automatically
The PSENscan Configurator offers the option of automatically finding a device available in
the network.
1. Select Device -> Search device.
The network is searched for connected devices of the PSEN sc M 3.0/5.5 08-12 series.
Connected devices of the PSEN sc M 3.0/5.5 08-12 series are listed under Network
environment.
To locate the PSEN sc M 3.0/5.5 08-12 series click the button
symbol is shown on the display of the selected PSEN sc M 3.0/5.5 08-12 series.
2. Double-click the safety laser scanner from Network environment.
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
INFORMATION
To ensure that PSENscan Configurator functions correctly, the files and dir-
ectories in the installation directory of PSENscan Configurator must not be
modified manually once installed (e.g. with the Windows Explorer or a text
editor).
INFORMATION
Use the correct IP address
A second IP address has been set up for internal functions of the safety
laser scanner. This address always follows directly after the IP address,
specified in the network settings.
Example: First address = 192.168.0.10, second address = 192.168.0.11
– Ensure that only one IP address is used when the following IP ad-
dress is not assigned.
. The wave
| 74