Configuration Of Zones - Pilz PSEN sc M 3.0 08-12 Operating Manual

Hide thumbs Also See for PSEN sc M 3.0 08-12:
Table of Contents

Advertisement

First commissioning
Fig.: Dual-channel connection of the safety laser scanner with 12-pin male connector on the input cir-
cuit of an evaluation device
Suitable Pilz evaluation devices are, for example:
}
PNOZmulti for monitoring safety laser scanners
Configure the safety laser scanner in PNOZmulti Configurator as a function element
"Light curtain" with switch type 3.
}
Automation system PSS 4000
The correct connection to the respective evaluation device is described in the operating
manual for the evaluation device. Connect the evaluation device according to the specifica-
tions in the selected evaluation device's operating manual.
9.3

Configuration of zones

Please note:
When these inputs/outputs are used, a pin has to be assigned for each used input or out-
put.
}
Outputs
– Warning
– Alarm 1
– Alarm 2
– Override status
– Muting lamp
}
Inputs
– Manual restart
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
External
supply voltage
24 V
24 V 0 V
Evaluation device
24 V
Input circuit
0 V
11
0 V
Configurable
via GUI
10
9
7
3
6
0 V
1
24 V
4
24 V
2
0 V
8
OSSD 2
5
OSSD 1
F.E.
12
PSENscan
| 78