Safety; Intended Use - Pilz PSEN sc M 3.0 08-12 Operating Manual

Hide thumbs Also See for PSEN sc M 3.0 08-12:
Table of Contents

Advertisement

Safety

3
Safety
3.1

Intended use

The safety laser scanners of the PSEN sc M 3.0/5.5 08-12 series are electrosensitive pro-
tective equipment of ESPE type 3. They are used to protect personnel and systems. The
safety laser scanners are designed to
}
safeguard the danger zone,
}
secure hazardous areas of vehicles and
}
protect the access within buildings.
The safety laser scanner may only be used for personal protection on machinery if
}
the hazardous state can be removed by the safety laser scanner and
}
the starting of the machine is controlled by the safety laser scanner and
}
the safety assessment prescribes no better detection capability than 40 mm, 70 mm.
The safety level PL d (Cat. 3)/SIL CL 2 is only achieved if
}
The safety outputs must be processed safety-related in 2-channel mode.
The restart of the machine or vehicle can be performed using a manual or an automatic re-
start.
}
It must not be possible to operate the pushbutton for manual restart from inside the
danger zone. The pushbutton must be located at a position from which there is a full, un-
obstructed view of the danger zone.
Prevent circumvention of the safety zone. This means that other electrosensitive protective
equipment and protective measures may be required in addition to the safety laser scanner.
These should be determined via a safety assessment based on the specific application
range and specific local conditions (e.g. official specifications).
Refer to IEC/TS 62046 to determine other necessary safeguards for securing the danger
zone.
Their application must fulfil the site's relevant national regulations (e. g. EN 60204-1,
NFPA 79:17-7).
The following is deemed improper use in particular
}
Any component, technical or electrical modification to the product,
}
Use of the product outside the areas described in this manual,
}
Use of the product outside the technical details (see
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Technical details [
106]).
| 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psen sc m 5.5 08-126d0000166d0000176d0000206d000021

Table of Contents