Example For An 12-Pin Connection - Pilz PSEN sc M 3.0 08-12 Operating Manual

Hide thumbs Also See for PSEN sc M 3.0 08-12:
Table of Contents

Advertisement

First commissioning
The OSSDs must switch to the OFF state each time the reference point changes bey-
ond the tolerance range, and the status of the OSSDs in the Monitoring work window
must show the changing of the reference points.
19. Select Download configuration to device, to transfer the configuration to the device.
Click Accept to activate the downloaded configuration in the connected device and re-
ject the existing configuration on the connected device.
Save the report in PDF format.
Click Reject to reject the downloaded configuration in the connected device and con-
tinue to use the existing configuration on the connected device. The downloaded con-
figuration in the connected device will be deleted.
9.3.2

Example for an 12-pin connection

Settings in PSENscan Configurator for a safety laser scanner with 12‑pin connection: Ver-
tical application with reference contour monitoring, 1 zone set, 1 warning, manual restart
Prerequisites
}
The safety laser scanner is already connected to the 12-pin male connector.
Procedure:
1. From the start page, select Create new configuration.
The window Device selection is displayed with one tab each Online and Overview of
all types.
2. Select the connected device from Overview of all types. Double-click the device.
The device is displayed in the work window and it can be configured.
3. Under Application, select VERTICAL and 12-pin connection.
Configuration
You can enter a title for the configuration under Name.
You can enter the name of the person who created the configuration under Author.
You can describe the configuration in detail under Description.
The Configurator Version is entered by the system and cannot be changed.
The Check sum is entered by the system and cannot be changed.
The Creation date is entered by the system and cannot be changed.
Device
You can enter a title for the connected device under Name.
Safety laser scanner arrangement
You can enter a title for the safety laser scanner arrangement under Name.
You can enter names for the devices in the safety laser scanner arrangement under
Device.
Click on the arrow
of OSSD pairs is already selected.
4. Select Warning zone = 0.
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
. The next window is opened: Output configuration. The number
| 82