Wiring
6.6
Wiring of the configurations
The configuration of the safety laser scanner PSEN sc M 3.0/5.5 08-12 series is carried out
in PSENscan Configurator on a configuration PC.
The wiring has to match the specifications in PSENscan Configurator.
6.7
Connect supply voltage and safety controller
The supply voltage connection is in the memory module that is protected by a screwed-on
cover. The memory module can be uninstalled for simpler connection.
1. Turn the safety laser scanner PSEN sc M 3.0/5.5 08-12 series for better access to the
memory module.
2. Loosen the M3 screws of the protective cover and remove the protective cover.
The screws are secured against loss and they cannot be removed.
3. Loosen the M3 screws [1] of the memory module and pull out the memory module.
The screws are secured against loss and they cannot be removed.
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
| 58