Configurable Inputs/Outputs; Wiring Of The Configurations; Connect Supply Voltage And Safety Controller - Pilz PSEN sc L 3 Series Operating Manual

Table of Contents

Advertisement

Wiring
When using the 12-pin connection, the configurable input at PIN 3 can be used for the fol-
lowing functions:
}
Restart
}
Reset
}
Restart or reset
}
EDM
}
Zone set switching
}
Muting 1 and 2
}
Dynamic activation of the muting state
6.2.2

Configurable inputs/outputs

When using the 8-pin connection, configurable input/output at PIN 1 can be used for the fol-
lowing functions:
}
Warning output
}
Alarms 1 or 2
}
Muting lamp
When using the 12-pin connection, the configurable inputs/outputs at PIN 7, 9, 10 and 11
can be used for the following functions:
}
Warning output
}
Alarms 1 or 2
}
Muting lamp
6.3

Wiring of the configurations

The configuration of the safety laser scanner PSEN sc L 3/5 series is carried out in
PSENscan Configurator on a configuration PC.
The wiring has to match the specifications in PSENscan Configurator.
6.4

Connect supply voltage and safety controller

The connection for the supply voltage is underneath a memory module. The memory mod-
ule can be uninstalled for simpler connection.
1. Turn the safety laser scanner PSEN sc L 3/5 series for better access to the memory
module.
2. Loosen the M3 screws of the protective cover and remove the protective cover.
The screws are secured against loss and they cannot be removed.