Prevent Esd Damage; Extend The Server To The Service Position - Oracle SPARC T7-2 Service Manual

Hide thumbs Also See for SPARC T7-2:
Table of Contents

Advertisement

Prevent ESD Damage

Many components housed within the chassis can be damaged by ESD. To protect these
components from damage, perform the following steps before opening the chassis for service.
1.
Prepare an antistatic surface to set parts on during the removal or installation
process.
Place ESD-sensitive components such as the printed circuit boards on an antistatic mat. The
following items can be used as an antistatic mat:
Antistatic bag used to wrap a replacement part
ESD mat
Disposable ESD mat (shipped with some replacement parts or optional components)
2.
Attach an antistatic wrist strap.
When servicing or removing server components, attach an antistatic strap to your wrist and then
to a metal area on the chassis.
See
"Safety Information" on page
Related Information
"Safety Information" on page 47

Extend the Server to the Service Position

You can service the following components with the server in the service position:
Drives
DVD drive
Power supplies
Fans
Fan modules
Memory risers
DIMMs
PCIe cards
SPM card
Battery
eUSB drive
47.
Prevent ESD Damage
Preparing for Service
57

Advertisement

Table of Contents
loading

Table of Contents