Install A Pcie Card Or Filler - Oracle SPARC T7-2 Service Manual

Hide thumbs Also See for SPARC T7-2:
Table of Contents

Advertisement

7.
Rotate the crossbar to an upright position (panel 1).
Carefully remove the PCIe card or filler from the card slot (panel 2).
8.
Replace with another PCIe card or filler before the server is connected to power
9.
again.
See
"Install a PCIe Card or Filler" on page
Related Information
"Install a PCIe Card or Filler" on page 131

Install a PCIe Card or Filler

This procedure requires that you handle components that are sensitive to ESD which
Caution -
can cause server components to fail.
1.
Take the necessary ESD precautions.
See
"Prevent ESD Damage" on page
2.
Ensure that the server is powered off and all power cords are disconnected from
the server power supplies.
See
"Removing Power From the Server" on page
Determine which slot to install the PCIe card in.
3.
If you are not replacing an existing PCIe card and need information about deciding which slot
to install the card in, see
4.
Disengage the PCIe card slot crossbar from its locked position by pulling it
toward the interior of the chassis.
The crossbar might already be disengaged if you removed a PCIe card or filler from that slot.
5.
Install the PCIe card or filler into the card slot and return the crossbar to its
closed and locked position.
131.
57.
"PCIe Card Configuration" on page
Install a PCIe Card or Filler
53.
125.
Servicing PCIe Cards
131