Oracle SPARC T7-2 Service Manual page 157

Hide thumbs Also See for SPARC T7-2:
Table of Contents

Advertisement

ok 0 activate-volume
Volume 0 is now activated
For more information on configuring hardware RAID on the server, refer to Servers
Note -
Administration.
Unselect the SCSI device.
8.
ok unselect-dev
9.
Confirm that you reactivated the volume.
ok probe-scsi-all
/pci@308/pci@1/usb@0/hub@1/storage@3
Unit 0
Disk
.
/pci@308/pci@1/usb@0/hub@1/storage@1
Unit 0
Removable Read Only device
.
/pci@308/pci@1/usb@0/hub@5/device@4/storage@0
Unit 0
Removable Read Only device
.
/pci@303/pci@1/scsi@0
.
FCode Version 1.00.64, MPT Version 2.05, Firmware Version 5.05.00.00
Target 9
Unit 0
Disk
SASDeviceName 5000cca02f0a1560 SASAddress 5000cca02f0a1561 PhyNum 0
.
Target 389 Volume 0
Unit 0
Disk
VolumeDeviceName 33b2999bca4dc677 VolumeWWID 03b2999bca4dc677
/pci@301/pci@1/scsi@0
.
FCode Version 1.00.64, MPT Version 2.05, Firmware Version 5.05.00.00
10.
Set the auto-boot? OpenBoot PROM variable to true so the server boots the OS
when powered on.
ok setenv auto-boot? true
Reboot the server.
11.
smiMICRON eUSB DISK
HGST
H101860SFSUN600G A770
LSI
Logical Volume
1112
SUNRemote ISO CDROM1.01
TEAC
DV-W28S-C
1172123568 Blocks, 600 GB
3000
583983104 Blocks, 298 GB
Servicing the Motherboard
Reactivate RAID Volumes
LT11
157

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARC T7-2 and is the answer not in the manual?

Questions and answers

Table of Contents