Interface overview, closed–loop drive control
High Standard and
High Performance
Table 4-3
Interface overview, High Standard and High Performance closed–loop drive control
Term.
Designa-
no.
tion
3)
AS1
X431
Relay start inhibit (feedback signal, terminal 663)
3)
AS2
X431
Relay start inhibit (feedback signal, terminal 663)
663
X431
Pulse enable: The "starting lockout" relay is operated with
terminal 663. On opening, the trigger pulses are inhibited
and the motor is switched into a torque–free condition.
9
X431
Enable voltage
P24
X431
+24 V supply for the brake control
BE1
X431
Output, brake control, axis 1
B1
X432
Input, external zero mark (BERO) axis 1
19
X432
Negative enable voltage
B2
X432
Input, external zero mark (BERO) axis 2
9
X432
Positive enable voltage
M24
X432
0 V supply for the brake control
BE2
X432
Output, brake control, axis 2
X34/X35
Test socket, DAC
X411
Motor encoder, axis 1
X412
Motor encoder, axis 2
X421
Direct position encoder, axis 1
X422
Direct position encoder, axis 2
X461
BERO input, axis 1
X462
BERO input, axis 2
X351
Equipment bus
X141/341
Drive bus
1) I=Input; O=Output; NC=NC contact; NO=NO contact (for a signal, NO=High/NC=Low)
2) The terminal may only be used to enable the associated drive group.
3) When connecting contacts AS1/AS2 in series, a contact voltage drop up to max. 0.2 V must be taken into account for
the lifetime of the contacts (100000 switching operations). For a 24 V switching voltage, due to the
non–linear contact characteristics, from experience, five contacts can be simply connected in series
without encountering any problems.
4) A UL–certified miniature fuse (max. 3.15 A) must be
provided at the supply for the brake control:
Value:
e.g. 3.15 AT/250 V; 5x20 mm UL
Company:
Wickmann–Werke GmbH
Annenstraße 113
58453 Witte, Germany
Order No.:
181
5) In order to increase the strength with respect to surge disturbances, for encoder cables > 30 m long, the screen
connection 6SN1162–0FA00–0AA2 can be used. In order to ensure noise immunity in compliance with the standard,
the encoder cable shields should be connected where the cable enters the control cabinet.
The permissible voltage range for the common mode component of the individual encoder signals (A+. A–. B+, B–, C+,
C–, D+, D–, R+, R–) is 1.5...3.5 V.
6) According to EN 60204–1 (Safety of Machinery) control transformers should be used when using AC control voltages.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
4.1 Closed–loop control with digital setpoint interface
Function
2)
4)
2)
5)
5)
5)
5)
4 Control Units
Type
Typ. voltage/limit
Max. cross–
1)
values
NC
max. 250 V AC/1 A,
30 V DC/2 A
I
+21 V ... 30 V
O
+24 V
I
+18 ... 30 V
O
max. 500 mA
I
+13 ... 30 V
O
0 V
I
+13 ... 30 V
O
+24 V
I
O
max. 500 mA
For the terminal
assignment, refer to
assignment, refer to
Table 4-4
For the terminal
assignment, refer to
assignment, refer to
Table
For the terminal
assignment, refer to
assignment, refer to
Table 4-6
4-87
section
2
1.5 mm
2
1.5 mm
2
1.5 mm
4
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents