Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 123

Simodrive 611 series drive converter
Table of Contents

Advertisement

5 Power Modules
5.1 Description
!
Power module,
internal cooling
Control unit
(refer to Chapter 4)
M3/0.8 Nm
Order number
Fig. 5-1
Power module with control unit
5-122
The equipment bus cable is included in the scope of supply of the power mod-
ule. The drive bus cables must be ordered separately for the digital system.
The current data of the power modules (PM modules) are normalized values to
which all of the control units refer. The output currents can be limited by the con-
trol unit being used.
Caution
After the control unit has been inserted, the retaining screws of the control unit
front panel must be tightened in order to establish a good electrical connection
to the module housing.
The power module is equipped with overload protection, which when corre-
spondingly dimensioned, prevents the motors and cables from being over-
loaded. The overload protection functions as described in the documentation
SINUMERIK 840D/810D drive functions, Chapter 2.4.1. It does not fully comply
with the requirements as specified in UL508C Version 2010, regarding cable
protection
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
50 mm power module
Type plate/Order No.
PE
© Siemens AG 2012 All Rights Reserved
02.12
10.04
02.07
05.01
M4/1.8 Nm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents