Description - Siemens 6SN1123-1AA00-0DA2 Configuration Manual

Simodrive 611 series drive converter
Table of Contents

Advertisement

Power Modules
5.1

Description

General
Together with the control module, the power module forms the drive module, for
feed or main spindle applications.
Motors that can be
The power modules can be used to operate the following motors:
connected
S
S
S
S
S
S
S
S
S
For special motors with a low leakage inductance (where the controller settings
are not adequate), it may be necessary to provide a series reactor in the form of
a 3–arm iron core reactor (not a Corovac reactor) and/or increase the inverter
pulse frequencies of the converter. Motors with a low leakage inductance are,
from experience, motors that can achieve high stator frequencies (maximum
motor stator frequency
current
Available power
A wide range of 1–axis or 2–axis power modules is available. These modules
modules
are graded according to the current ratings and can be supplied with three dif-
ferent cooling techniques.
The current–related data refers to the series–preset values. At higher frequen-
cies of the fundamental waves or for higher clock cycle frequencies, ambient
temperatures and installation altitudes above 1000 m above sea level, power
deratings apply as subsequently listed.
Wiring
Matched, pre–assembled cables are available to connect the motors. Ordering
information is provided in the "Motors" section of the NC 60 catalog.
Shield terminal plates are available to meet EMC requirements when using
shielded power cables.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
1FT6, 1FK6 and 1FK7 servo motors
1FW6 built–in torque motors (direct drives)
1FN linear motors
1PH main spindle motors
Standard induction motors; if IM operation is selected, only inverter pulse
frequencies of 4 kHz and 8 kHz are permissible.
1PM hollowshaft motors for main spindle drives (direct drives)
1FE1 main spindle motors
2SP1 motor spindle
Third–party motors, if according to the motor manufacturer the motor meets
the requirements for sine modulation, insulation, and dV/dt resistance (see
Chapter 8.1).
300 Hz) or motors with a high rated current (rated
>
85 A).
>
5
5
5-121

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents