Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 168

Simodrive 611 series drive converter
Table of Contents

Advertisement

02.12
05.01
Table 6-9
Technical specifications, I/R modules
Internal cooling
6SN11 45-
External cooling
6SN11 46-
Hose cooling
6SN11 45-
Infeed/regenerative
feedback
kW
Rated power (S1)
kW
S6 power
kW
Peak power (400 V)
Sinusoidal operation in-
Use for dimensioning the installation, not for calculating the power!
put currents (AC
)
RMS
Rated current (400 V)
A
rms
Squarewave operation
Use for dimensioning the installation, not for calculating the power!
input currents (AC
)
RMS
Rated current (400 V)
A
rms
Use for dimensioning the installation, not for calculating the power! (calculated)
Rated current (400 V)
A
rms
unregulated operation
Connection data
Voltage (power)
V
rms
Voltage (electronics)
V
Power supply
V
rms
Frequency
Hz
2
Connection cross–sec-
mm
tion
Output voltage
V
Module width
mm
Type of cooling
Internal cooling
3
(volumetric flow rate)
(volumetric flow rate)
m
m /h
/h
1)
External cooling
Hose cooling
Hose cooling
Losses
Internal cooling
W
External cooling
W (int./ext.)
Hose cooling
W (int./ext.)
Efficiency η
Weight
Internal cooling
kg
External cooling
kg
Hose cooling
kg
1) For a module width of 300 mm with external cooling, mounting frames are required that must be ordered separately.
The fan assembly required to mount the built–on fan is included in the scope of supply of the mounting frame.
The built–on fan must be ordered separately! Mounting frames are also available for smaller module widths. However,
these are not required if openings are cut out in the rear cabinet panel for the module heatsinks as shown in this
Configuration Manual.
2) External power supply for main contactor control required (see Chapter 6.2.5).
3) ) Must be separately ordered: Mounted fan, 6SN1162–0BA02–0AA2
4) See the diagram with pipe cooling in Chapter 2.7.1, Fig. 2-7
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
V
V
V
V
1BA0
-0BA
1BA0
-0CA
V
V
V
V
1BB0
-0BA
1BB0
-0CA
-
-
16
36
21
47
35
70
27
60.5
30
67
33
74
refer to Chapter C.1.3, Table 3.5
refer to Chapter C.1.3, Table 3.5
At the DC link with 600/625/680 V DC or supplied in parallel, AC and DC con-
nection or DC connection only.
50 to 60 10%
Max. 16
Max. 50
regulated: 600/625; unregulated: 490...680 (line supply–dependent)
100
200
Fan
Fan
56
56
112
112
Fan
Fan
320
585
50/270
50/535
0.97
0.97
10.5
15.5
10.5
15.5
6 Infeed Modules
6.4 Technical data
V
V
V
V
1BA0
-0DA
1BB0
-0EA
V
V
V
V
1BB0
-0DA
1BB0
-0EA
V
V
V
V
1BB0
-0DA
1BB0
-0EA
2)
55
80
71
104
91
131
92.5
134
102
149
114
165
Max. 95
Max. 95
300
300
Fan
Built–on fan
3)
112
400
Mounting frame (Bestell-Nr. 6SN1162–
0BA04–0EAV) with fan assembly and built–on
fan (6SN1162–0BA02–0AA2
Kit for hose cooling with fan
745
1280
115/630
190/1090
115/630
190/1090
0.97
0.97
26
26
26
26
26
26
V
V
1BB0
-0FA
V
V
1BB0
-0FA
V
V
1BB0
-0FA
2)
120
156
175
202
223
248
Max. 150
300
1)
Built–on fan
3)
400
1950
290/1660
290/1660
0.97
29
29
29
6-167