Braking Operation - Siemens 6SN1123-1AA00-0DA2 Configuration Manual

Simodrive 611 series drive converter
Table of Contents

Advertisement

02.07
05.01
The sum of P
and main spindles that are simultaneously operated. This calculated power
must be less than the peak power of the regenerative feedback module.
1.3.3

Braking operation

With the UI modules, only deceleration with pulsed resistors is possible.
With I/R modules, a regenerative feedback of excess energy to the supply
system also occurs. For required braking operations in the event of a power
failure, the braking module and pulsed resistors are also needed.
The regenerative feedback power is dependent on the available energy to be
braked in the system:
S
S
S
S
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
and P
should be calculated from all of the feed axes
S FD
S MSD
The mass
Speed/velocity
Braking ramps/braking time
Efficiencies
1 Overview of the Drive System
1.3 Engineering a drive
1
1-35