Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 144

Simodrive 611 series drive converter
Table of Contents

Advertisement

05.01
Relay contact
Ready signal
Relay contact for group signal I
and motor overtemperature
Pulse enable
Enable voltage
Enable voltage
Drive enable
Reference potential for enable
voltage
P24
P15
N15
N24
M
M
RESET (R+term.15)
Enable voltage
Set–up operation
Contactor energization, start
Signaling contact,
line contactor
Enable signal for internal line
contactor
Signaling contact, start inhibit
(NC contact)
DC link power supply for buffering
power failures
External infeed for the electronics power supply
External infeed for the electronics power supply
External infeed for the electronics power supply
LED display
Electronics power
red
supply faulted
Device is not ready,
green
no enable signal (term.
63, 64 or 48)
red
Line supply fault
1) Jumpers inserted when the equipment is supplied
2) For UI modules, there is no X172
Fig. 6-2
Interfaces, infeed module (UI module) or infeed/regenerative feedback module (16 to 55 kW I/R module)
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
74
NC
nc
contact
73.2
73.1
NO
nc
contact
72
5.3
2
t
5.2
5.1
63
9
9
64
19
7
45
44
10
15
15
R
9
112
48
111
213
113
NS1
NS2
AS1
AS2
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
5 V voltage
red
level faulted
Unit ready
yellow
(DC link
pre–charged)
DC link
red
overvoltage
6 Infeed Modules
6.1 Description
X111
X121
X141
1)
X161
1)
X171
2)
X172
LED
displays
X351
X181
1)
P600
DC link connection
M600
Line
connection
U1 V1 W1 X131 PE
6
Equipment
bus
supply
6-143