P24 terminals
+24 V supply for the brake control, tolerance range +18...30 V
M24 terminals
0 V supply for the brake control
Terminals BE1,
Output, brake control axis 1 and axis 2,
BE2
max. current is 500 mA
A UL–certified miniature fuse (max. 3.15 A) must be provided at the supply for
the brake control:
Value:
Company:
Order No.:
Reader's note
Connection example for a holding brake, refer to Chapter 4.1.1.
Terminals B1, B2
Input, external zero mark (BERO), axis 1 and axis 2.
Rated operating voltage: +13 to 30 V
If the referencing of the encoder zero pulses cannot be evaluated, then a signal
supplied from a mounted sensor (BERO) can be fed via this input as an "equiv-
alent zero mark".
DAC assignment
Three 8–bit digital/analog converter (DAC) channels are available. An analog
image of various drive signals can be connected through to a test socket via
these converters.
The three DAC channels are assigned the following drive signals by default:
DA1: Current setpoint
DA2: Speed setpoint
DA3: Actual speed
M:
Resolution: 8 bits
Rated operating voltage: 0...5 V
Maximum current: 3 mA
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
e.g. 3.15 AT/250 V; 5x20 mm UL
Wickmann–Werke GmbH
Annenstrasse 113
58453 Witte, Germany
181
Reference point (ground)
8 Important Circuit Information
8.4 Drive modules
Default shift factor: 4
Default shift factor: 6
Default shift factor: 6
8
8-251

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents