6 Infeed Modules
6.1 Description
Relay contact
Ready signal
Relay contact for group signal I
and motor overtemperature
Reference potential for enable
voltage
Enable signal for internal line
contactor
Signaling contact, start inhibit (NC
contact)
DC link power supply for buffering
power failures
External infeed for the electronics power supply
External infeed for the electronics power supply
External infeed for the electronics power supply
LED display
Electronics power
red
supply faulted
Device is not ready,
green
no enable signal (term.
63, 64 or 48)
red
Line supply fault
1) Jumpers inserted when the equipment is supplied
Fig. 6-3
Infeed/regenerative feedback module (80 and 120 kW I/R module) interfaces
6-144
74
NC
nc
73.2
contact
73.1
NO
nc
contact
72
5.3
2
t
5.2
5.1
Pulse enable
63
9
Enable voltage
9
Enable voltage
64
Drive enable
19
P24
7
P15
45
N15
44
N24
10
M
15
M
15
RESET (R+term.15)
R
Enable voltage
9
112
Set–up operation
48
Contactor energization, start
111
Signaling contact,
213
line contactor
113
NS1
NS2
AS1
AS2
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
5 V voltage
red
level faulted
Unit ready
yellow
(DC link
pre–charged)
DC link
red
overvoltage
Line supply connection
X111
X121
X141
1)
X161
1)
X171
X172
LED
displays
X181
1)
P600
M600
L1 L2 X131
U1
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
05.08
05.01
X351
Equipment
bus
DC link connection
PE
V1
W1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents