Kw Ui Module Interface Overview - Siemens 6SN1123-1AA00-0DA2 Configuration Manual

Simodrive 611 series drive converter
Table of Contents

Advertisement

6 Infeed Modules
6.2 Interface overview
6.2.2

5 kW UI module interface overview

Table 6-2
Interface overview, 5 kW UI modules
Term.
Desig-
No.
nation
U1
X1
Line supply connection
V1
W1
PE –
Protective conductor
X131
Electronics M
X351
Equipment bus
Grounding bar
P600
DC link
M600
M500
X181
DC link power supply
P500
X181
DC link power supply
1U1
X181
Output L1
2U1
X181
Input L1
1V1
X181
Output L2
2V1
X181
Input L2
1W1
X181
Output L3
2W1
X181
Input L3
5.3
X121A
Relay contact
5.2
X121A
Group signal
5.1
X121A
2
I
t/motor temperature
nc
X121A
74
X121B
Relay signal
73.2
X121B
Ready/
73.1
X121B
fault
72
X121B
2)
63
X141AX
Pulse enable
2)4)
9
141A
FR+
2)4)
9
X141A
FR+
2)
64
X141A
Drive enable
5)
R
X141A
RESET
19
X141A
FR–, reference ground enable
voltage
1) I = input; O = output; NC = NC contact; NO = NO contact
2) Term. 19 is the reference ground (connected through 10 kW to the general reference ground X131 inside the module)
Terminal 15 must not be connected to PE, to terminal 19 or to external voltage sources
Terminal 19 can be connected to X131.
The terminal may be used exclusively for enabling the associated drive group.
3) The grounding clip is used to ground the DC link M busbar through 100 kΩ (must be closed;
the grounding clip must be opened if the system is subject to a high–voltage test).
4) max. current load of terminal 9 – terminal 19  1 A
Notice: For the 5 kW, there are no terminals 7, 45, 44 and 10.
5) RESET = resets the fault memory, edge–triggered for the complete drive group
(terminal "R" ! Term. 19 = RESET)
only use copper cables dimensioned for an operating temperature w 60°C.
:
6) For UL certification
7) In accordance with EN 60204–1 (machine safety),
control transformers must be used for AC control voltages.
6-150
Type
Function
1)
I
I
I
I/O
3)
I/O
I/O
I
I
O
I
O
I
O
I
NC
NO
I
NC
I
I
NO
I
O
O
I
I
O
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Typ. voltage/limit values
3–ph. 400 V AC
0 V
0 V
Various
–300 V
+300 V
–300 V
–300 V
+300 V
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
1–ph. 50 V DC/0.5 A/12 VA max
1–ph. 5 V DC/3 mA min
1–ph.250 V AC/50 V DC/2 A max
5 V DC/3 mA min
+13 V...30 V/R
= 1.5 kΩ
E
+24 V
+24 V
+13 V...30 V/R
= 1.5 kΩ
E
terminal 19/R
= 10 kΩ
E
© Siemens AG 2012 All Rights Reserved
02.07
02.03
05.08
05.01
Max. cross–section
6)
2
4 mm
finely–stranded
without conductor end
sleeves
2
6 mm
with pin–type
cable lug
M5 thread
M4 thread
34–core ribbon cable
Busbar
Conductor bar
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
7)
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm

Hide quick links:

Advertisement

Table of Contents
loading