Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 48

Simodrive 611 series drive converter
Table of Contents

Advertisement

02.12
05.01
Table 2-2
Ambient conditions
Designation
S
Vibratory load
Long–term storage in the transport packaging
S
Transport in the transport packaging
S
Operation
S
Shock load
Long–term storage in the transport packaging
S
Transport in the transport packaging
S
Operation
Modules/devices without drive:
Modules/devices with drive:
S
Protection
Modules with internal cooling
S
against ingress
Modules with external cooling/pipe cooling
of solid foreign
Heatsink in cooling area
bodies and water
Electronics area
Transportation
Transportation
Temperature range
and storage
and storage
Dew–point temper-
ature t
and relative
d
d
air humidity U
air humidity U
Relevant Standards
Ambient climatic
Temperature range:
for PM/NE modules
conditions in
(100% load):
operation
Current/power der-
ating from +40 °C
onwards:
Dew–point temper-
ature t
and relative
d
d
air humidity U
air humidity U
Temperature
change
Condensation
Atmospheric pres-
sure
Gases that can
have a negative im-
pact on the function
Relevant Standards
1) Supplementary measure is required, if the work to be carried out close to the DC link busbar (DC link cover at the last modu-
le).
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Description
Class 1M2 in accordance with EN60721–3–1
Class 2M3 in accordance with EN60721–3–2
Test values:
Frequency range: 10 Hz to 56 Hz
With constant 0.075 mm deflection
Frequency range: 58 Hz to 200 Hz
With constant 1 g acceleration
Class 1M2 in accordance with EN60721–3–1
Class 2M3 in accordance with EN60721–3–2
Test values:
5 g/11 ms
5 g/30 ms
–40 °C – +70 °C
Annual average
U = 75%
td = 17 °C
On 30 days (24 h) annually
U = 95%
td = 24 °C
These days should be naturally distributed over the complete year.
On the other days (<24 h)
U = 85%
td = 24 °C
But maintaining the annual
average
DIN EN 60068–2–1
DIN EN 60068–2–2
DIN EN 60068–2–3
DIN EN 61800–5–1
0 °C – +55 °C
+40 °C
2.5 %/°C
Annual average
U = 75%
td = 17 °C
On 30 days (24h) annually
U = 95%
td = 24 °C
These days should be naturally distributed over the complete year.
On the other days (<24 h)
U = 85%
td = 24 °C
But maintaining the annual
average
Within one hour:
max. 10 K
Within 3 minutes:
max. 1 K
Not permissible
min. 860 mbar (86 kPa)
max. 1080 mbar (108 kPa)
acc. to DIN 40046, Part 36 and Part 37
DIN EN 60068–2–1
DIN EN 60068–2–2
DIN EN 60068–2–3
DIN EN 61800–5–1
2 System Configuration
2.2 Ambient conditions
1)
IP20
IP54
IP20
2
2-47

Hide quick links: