Description
Sets/Reads the maximum number of iterations for the DC control voltage-setting loops
Parameter
Range
Preset value
Unit
Resolution
Equivalent key
PN Menu -> DC Control Voltage -> Auto Freq Control -> Max Iteration
SP Menu -> DC Control Voltage -> Auto Freq Control -> Max Iteration
FP Menu -> DC Control Voltage -> Auto Freq Control -> Max Iteration
TR Menu -> DC Control Voltage -> Auto Freq Control -> Max Iteration
USER Menu -> DC Control Voltage -> Auto Freq Control -> Max Iteration
:SOURce:VOLTage:CONTrol:AFC:LIMit:HIGH
Syntax
:SOURce:VOLTage:CONTrol:AFC:LIMit:HIGH <numeric>
:SOURce:VOLTage:CONTrol:AFC:LIMit:HIGH?
Description
Sets/Reads the maximum DC control voltage limit
Parameter
Range
Preset value
Unit
Resolution
Equivalent key
PN Menu -> DC Control Voltage -> Auto Freq Control -> Max Ctrl Voltage Limit
SP Menu -> DC Control Voltage -> Auto Freq Control -> Max Ctrl Voltage Limit
FP Menu -> DC Control Voltage -> Auto Freq Control -> Max Ctrl Voltage Limit
TR Menu -> DC Control Voltage -> Auto Freq Control -> Max Ctrl Voltage Limit
USER Menu -> DC Control Voltage -> Auto Freq Control -> Max Ctrl Voltage Limit
:SOURce:VOLTage:CONTrol:AFC:LIMit:LOW
Syntax
:SOURce:VOLTage:CONTrol:AFC:LIMit:LOW <numeric>
7
:SOURce:VOLTage:CONTrol:AFC:LIMit:HIGH
<Numeric>
1 to 99
10
-
-
<Numeric>
-15 to 35
35
V
100u
SCPI Command Reference
337