Agilent Technologies E5052A Programmer's Manual page 489

Signal source analyzer
Hide thumbs Also See for E5052A:
Table of Contents

Advertisement

event register.
Table B-15
Status Bit Definitions of Questionable Limit TR1 Status Event Register
Bit
Position
0
1
2
3
4
5-15
Issuing the *CLS command will clear all of the bits in the questionable limit TR1 status
event register.
Table B-16
Status Bit Definitions of Questionable Limit USER1 Status Event Register
Bit
Position
0
1
2
3
4
5
6
7
8
Appendix B
Name
Not used
Trace 1 Limit Test Fail
Trace 2 Limit Test Fail
Trace 3 Limit Test Fail
Trace 4 Limit Test Fail
Not used
Name
Not used
Trace 1 Limit Test Fail
Trace 2 Limit Test Fail
Trace 3 Limit Test Fail
Trace 4 Limit Test Fail
Trace 5 Limit Test Fail
Trace 6 Limit Test Fail
Trace 7 Limit Test Fail
Trace 8 Limit Test Fail
Status Reporting System
Status Register Structure
Description
Always 0.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 1.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 2.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 3.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 4.
Always 0.
Description
Always 0.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 1.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 2.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 3.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 4.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 5.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 6.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 7.
Set to "0" when a measurement cycle begins;
set to "1" when the measurement cycle finishes and
returns "fail" as the limit test result for trace 8.
489