Seed Box Seed Rate Adjustment - Landoll Brillion SL10 Operator's Manual

Hide thumbs Also See for Brillion SL10:
Table of Contents

Advertisement

OPERATION

Seed Box Seed Rate Adjustment

• To Prevent damage to seed meters, do not
apply excessive force to adjusting nuts. This
is especially important when closing meters
as seed in flutes can be pinched between
cut-off and washer in seed cup.
• Do not close meters more than 1/8" when
there is seed in the meters without rotating
the seed shaft to prevent damage to the
rotating washers and retainer rings in the
seed meters.
• Do not attempt to open meters more than 1".
(Feed rolls could become disengaged from
washer in the seed cup.)
NOTE
To avoid Seed Meter damage, if there is seed in the
Meters, decrease rate in small increments. Decrease rate
no more than one nut revolution and rotate Seed Shaft to
purge seed from Meters. Continue adjustment as
needed.
NOTE
Before filling with seed be sure Seed Shaft turns freely
and Seed Meters are free of any foreign matter.
Wrenches for adjustment are stored on a Pin at the back
of the Transmission. See Figure 3-9.
Adjustment
Wrenches
Figure 3-9: Adjustment Wrenches
3-8
WARNING
IMPORTANT
If equipped, the Clutch must be disengaged when
Seed Shafts are turned manually for Calibration.
Seed Rate Charts specific to Seeder Model are located
inside the Seed Box Cover and in this manual. See
Figure 3-11. It should be used as a general guide only.
Based upon your Seeder Model.
Because of seed variation, a more accurate rate can be
determined by turning the 15/16" Hex Nut on the
Transmission to calibrate the Seeder. See "Calibration
for Unlisted Seeds" on Page 3-10.
On the right side, the Seed Rate for the Seed Meters can
be set by adjusting the Seed Rate Adjusting Nut and
Adjusting Screw. See Figure 3-9.
IMPORTANT
Do Not Loosen or Adjust the 1/2-13 Locknut. See
Figure 3-10.
Adjusting
Screw
DO NOT
Loosen or Adjust
1/2-13 Locknut
1-8 Nut
Figure 3-10: Seed Box Seed Rate Adjustment
1. To increase the rate of seeding: loosen the 1-8 Nut
on inside of the Bearing and turn the outer Seed Rate
Adjusting Nut to the desired higher number setting,
then tighten the 1-8 Nut using supplied wrenches.
2. To decrease the rate of seeding: loosen the Seed
Rate Adjusting Nut and set it to the new desired
position; then tighten the 1-8 Nut using supplied
wrenches.
Seed Meters discharge to the front of the machine to aid
the operator in determining proper operation. In addition,
reflective amber decals are placed on the seed shaft to
indicate rotation.
DO NOT
Loosen or Adjust
1/2-13 Locknut
Seed Shaft
Seed Rate
Adjusting Nut
Bearing
Op SeedRateAdj 8-10-12
1P342-0621

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents