11.3.6 Device identification (Read Device Identification)

The wind transmitter supports the MODBUS function 0x2B (Read Device Identification) with
the MEI type 0x0E. This enables the MODBUS Master to recognize the wind transmitter.
Function:
MEI type:
Read Device ID code:
Supported objects:
Object
Object name / de-
Id
scription
0x00
VendorName
0x01
ProductCode
0x02
FirmwareVersion
0x03
VendorUrl
0x04
ProductName
0x05
ModelName
0x80
HW-ID
1
: The maximum length of a value is 32 bytes.
2
: The quotation marks are not part of the character string.
3
: The HW-ID (object id: 0x80) consists of 22 bytes which represent 11 binary bytes.
© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
Phone +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com · www.thiesclima.com
0x2B / 0x0E (Read Device Identification)
0x0E
1, 2, 3 (stream access)
Type
Category
ASCII string
Basic
ASCII string
ASCII string
ASCII string
Regular
ASCII string
ASCII string
ASCII string
Extended
Table 9: Device Identification
1, 2
Value
"Adolf Thies GmbH &CO. KG"
"4.3352.00.400"
"V04.xx"
"www.thiesclima.com"
"WIND VELOCITY
TRANSMITTER"
"WIND TRANSMITTER FIRST
CLASS ADVANCED X"
"304A37393634110B000700"
3
021814/03/21
Page 68 of 86